Commercial bathroom stall dimensions vary depending on the stall type, restroom layout and accessibility requirements. A standard bathroom stall is commonly 36 inches wide and 60 inches deep. An ADA wheelchair-accessible stall must generally be at least 60 inches wide and provide a 32-inch minimum clear door opening.
Use this guide to compare standard, ADA and ambulatory bathroom stall dimensions before measuring your restroom or ordering commercial bathroom partitions.
Standard Bathroom Stall Dimensions at a Glance
| Stall Type | Typical Width | Typical Depth | Door Opening |
|---|---|---|---|
| Standard Stall | 36″ | 60″ | 24″–30″ |
| ADA Wheelchair-Accessible Stall | 60″ minimum | 56″ minimum with a wall-hung toilet; 59″ minimum with a floor-mounted toilet | 32″ minimum clear opening |
| Ambulatory Accessible Stall | 35″–37″ | 60″ minimum | 32″ minimum clear opening |
These measurements offer a general planning reference. Always verify current federal, state and local accessibility and building-code requirements before finalizing your restroom layout.
What Are Standard Bathroom Stall Dimensions?
A standard commercial bathroom stall is commonly 36 inches wide and 60 inches deep. The door is usually between 24 and 30 inches wide, depending on the stall layout and available space.
Standard dimensions may vary based on:
- The restroom’s overall size
- Toilet location
- Door width and swing direction
- Partition material
- Mounting style
- Privacy height
- Local building requirements
Bathroom partitions can be sized to fit the finished dimensions of your project. Always measure the actual restroom instead of assuming that standard sizes will fit.
What Are ADA Bathroom Stall Dimensions?
A wheelchair-accessible bathroom stall must provide enough room for a person using a wheelchair to enter, maneuver and use the toilet safely.
Common ADA bathroom stall dimensions include:
- 60 inches minimum width
- 56 inches minimum depth for a wall-hung toilet
- 59 inches minimum depth for a floor-mounted toilet
- 32 inches minimum clear door opening
- Toilet centerline positioned 16 to 18 inches from the side wall or partition
- Required grab bars and accessible hardware
ADA stall doors commonly swing outward. A door may swing inward only when it does not overlap the required clear floor space or fixture clearances.
Always check the complete ADA standards and any state or local requirements before approving the final layout.
is almost always the safest choice.
What Are Ambulatory Bathroom Stall Dimensions?
To meeAn ambulatory accessible stall supports people who can walk but may need grab bars on both sides of the toilet.
Typical ambulatory stall dimensions include:
- 35 to 37 inches wide
- 60 inches minimum depth
- 32 inches minimum clear door opening
- Grab bars on both sides
- Toilet centerline positioned 17 to 19 inches from a side wall or partition
An ambulatory accessible stall may be required in larger public restrooms based on the total number of toilet compartments and urinals.
What Is the Standard Bathroom Stall Door Size?
A standard bathroom stall door is commonly 24 to 30 inches wide. The exact size depends on the stall width, partition layout and door swing.
Accessible stall doors must provide at least a 32-inch clear opening when opened to 90 degrees. The clear opening is the usable space between the open door and the opposite stop or partition—not simply the width of the door itself.
When measuring a stall door, record:
- The proposed door width
- The clear opening
- Inward or outward swing
- Left-hand or right-hand operation
- Available clearance outside and inside the stall
Door swing and hardware placement should be shown clearly on the restroom layout.
How Tall Are Commercial Bathroom Partitions?
Standard commercial bathroom partition doors and panels are commonly between 55 and 58 inches tall. They are typically installed 12 to 14 inches above the finished floor, depending on the material and partition system.
The final height can vary based on:
- Partition material
- Mounting style
- Standard or increased-privacy design
- Ceiling height
- Project specifications
Increased-privacy partitions use taller doors and panels with smaller gaps above and below the components. Floor-to-ceiling systems can provide additional stability and privacy in busy commercial restrooms.
Confirm the selected material and mounting style before using standard height measurements for your project.
Common Bathroom Partition Mounting Styles
The mounting style affects the partition’s appearance, support requirements and installation.
Overhead-Braced Partitions
Overhead-braced partitions attach to the floor and use a metal headrail across the top for added support. This is the most common mounting style because it works well in many commercial restroom layouts.
Floor-Mounted Partitions
Floor-mounted partitions anchor to the floor without an overhead rail. They provide a clean appearance but require a strong, level floor for proper support.
Ceiling-Hung Partitions
Ceiling-hung partitions leave the floor clear, which can make cleaning easier. This style requires sufficient structural support above the ceiling.
Floor-to-Ceiling Partitions
Floor-to-ceiling partitions anchor at both the floor and ceiling. They offer additional stability and work well in high-traffic facilities.
How to Measure for Bathroom Partitions
Accurate measurements help ensure your bathroom partitions fit correctly and operate as intended. Measure from finished surfaces and record all dimensions in inches.
Step 1: Measure the Overall Restroom Area
Record the complete area where the bathroom partitions will be installed, including:
- Wall-to-wall width
- Front-to-back depth
- Ceiling height
- Floor type
- Wall construction
- Location of toilets and fixtures
Measure the room in several places. Walls and floors are not always perfectly straight or level.
Step 2: Measure Each Stall Width
Measure the planned width of each stall from finished wall to partition, or from partition to partition.
Record each stall separately instead of assuming all stalls have the same width. Small differences can affect panel, pilaster and door sizes.
Step 3: Measure the Stall Depth
Measure from the finished back wall to the proposed front of the stall. The front line is where the doors and pilasters will be installed.
Allow enough room for:
- Toilet placement
- Door operation
- Required clearances
- User movement
- Accessible turning and maneuvering space
Step 4: Record the Toilet Location
Measure from the finished side wall to the centerline of each toilet. Also note whether the toilet is wall-hung or floor-mounted.
The toilet type and location are especially important when determining accessible stall depth and clearance.
Step 5: Determine Door Swing
Clearly mark whether each door will swing inward or outward. Also record whether the door should operate from the left or right.
Make sure the door will not interfere with:
- The toilet
- Grab bars
- Sinks or accessories
- Other stall doors
- Required accessible clearances
Step 6: Record All Obstructions
Include anything that may interfere with the partitions or hardware, such as:
- Pipes
- Baseboards
- Wall tile
- Floor drains
- Radiators
- Vents
- Windows
- Electrical outlets
- Existing bathroom accessories
Provide the size and exact location of each obstruction.
Step 7: Confirm the Mounting Style
Choose the mounting style before finalizing the measurements. Floor construction, ceiling structure and overall room height can affect which mounting styles will work.
If you are unsure, send your restroom measurements and layout to our team for review.
Request a Free Partition Quote
Fast, accurate, and tailored to your layout.
Why Accurate Bathroom Stall Measurements Matter
ven a small measurement mistake can lead to:
- Incorrect door or panel sizes
- Hardware alignment problems
- Doors that do not open properly
- Installation delays
- Costly replacement parts
- Accessibility issues
Measure from finished walls, tile and flooring—not unfinished construction surfaces. Check every measurement at least twice and use the smallest measurement when walls are uneven.
Common Bathroom Stall Measuring Mistakes
Measuring Only Once
Take every measurement at least twice. Measure in multiple locations when a wall or floor appears uneven.
Measuring From Unfinished Walls
Tile, drywall and wall panels reduce the available space. Always use finished dimensions when possible.
Forgetting the Door Swing
An inward-swinging door needs enough room to clear the toilet and required floor space. Outward-swinging doors need sufficient clearance outside the stall.
Leaving Out Obstructions
Pipes, vents, baseboards and bathroom accessories can interfere with panels, pilasters and mounting hardware.
Assuming Every Stall Is the Same Size
Measure each stall individually. Small differences in wall placement or toilet location can change the required partition sizes.
Guessing ADA Measurements
Do not rely on a standard layout without checking the actual space. Accessible stalls must meet requirements for width, depth, door clearance, toilet placement and maneuvering space.
Common Bathroom Stall Measuring Mistakes
The material does not usually change the required ADA clearances, but it can affect component thickness, available sizes and installation details.
We offer:
- Powder-coated steel bathroom partitions
- Solid plastic bathroom partitions
- Stainless steel bathroom partitions
Powder-coated steel offers an economical option for many commercial restrooms. Solid plastic provides excellent moisture resistance and works well in high-traffic or humid environments. Stainless steel offers a clean, professional appearance with reliable performance.
Bathroom Stall Dimension FAQs
A standard commercial bathroom stall is commonly 36 inches wide and 60 inches deep. Actual dimensions can vary based on the restroom layout and local requirements.
A standard commercial stall is commonly 36 inches wide. Confirm the required size with the applicable building code and project specifications.
A wheelchair-accessible stall must generally be at least 60 inches wide. The minimum depth is typically 56 inches with a wall-hung toilet or 59 inches with a floor-mounted toilet.
Yes. Commercial bathroom partitions can be sized for the restroom’s finished dimensions, material, mounting style and layout.
Get Help With Your Bathroom Stall Layout
Not sure whether your bathroom stall dimensions are correct? Send us your measurements, sketch or restroom layout. Our experienced team can review the information and help determine the partition sizes needed for your project.
We supply powder-coated steel, solid plastic and stainless steel bathroom partitions for commercial restrooms nationwide.