Bathroom Stall Dimensions: Standard and ADA Sizes

Commercial bathroom stall dimensions vary depending on the stall type, restroom layout and accessibility requirements. A standard bathroom stall is commonly 36 inches wide and 60 inches deep. An ADA wheelchair-accessible stall must generally be at least 60 inches wide and provide a 32-inch minimum clear door opening.

Use this guide to compare standard, ADA and ambulatory bathroom stall dimensions before measuring your restroom or ordering commercial bathroom partitions.

Stall TypeTypical WidthTypical DepthDoor Opening
Standard Stall36″60″24″–30″
ADA Wheelchair-Accessible Stall60″ minimum 56″ minimum with a wall-hung toilet;
59″ minimum with a floor-mounted toilet
32″ minimum clear opening
Ambulatory Accessible Stall35″–37″60″ minimum32″ minimum clear opening

These measurements offer a general planning reference. Always verify current federal, state and local accessibility and building-code requirements before finalizing your restroom layout.

A standard commercial bathroom stall is commonly 36 inches wide and 60 inches deep. The door is usually between 24 and 30 inches wide, depending on the stall layout and available space.

Standard dimensions may vary based on:

  • The restroom’s overall size
  • Toilet location
  • Door width and swing direction
  • Partition material
  • Mounting style
  • Privacy height
  • Local building requirements

Bathroom partitions can be sized to fit the finished dimensions of your project. Always measure the actual restroom instead of assuming that standard sizes will fit.

A wheelchair-accessible bathroom stall must provide enough room for a person using a wheelchair to enter, maneuver and use the toilet safely.

Common ADA bathroom stall dimensions include:

  • 60 inches minimum width
  • 56 inches minimum depth for a wall-hung toilet
  • 59 inches minimum depth for a floor-mounted toilet
  • 32 inches minimum clear door opening
  • Toilet centerline positioned 16 to 18 inches from the side wall or partition
  • Required grab bars and accessible hardware

ADA stall doors commonly swing outward. A door may swing inward only when it does not overlap the required clear floor space or fixture clearances.

Always check the complete ADA standards and any state or local requirements before approving the final layout.

is almost always the safest choice.

To meeAn ambulatory accessible stall supports people who can walk but may need grab bars on both sides of the toilet.

Typical ambulatory stall dimensions include:

  • 35 to 37 inches wide
  • 60 inches minimum depth
  • 32 inches minimum clear door opening
  • Grab bars on both sides
  • Toilet centerline positioned 17 to 19 inches from a side wall or partition

An ambulatory accessible stall may be required in larger public restrooms based on the total number of toilet compartments and urinals.

A standard bathroom stall door is commonly 24 to 30 inches wide. The exact size depends on the stall width, partition layout and door swing.

Accessible stall doors must provide at least a 32-inch clear opening when opened to 90 degrees. The clear opening is the usable space between the open door and the opposite stop or partition—not simply the width of the door itself.

When measuring a stall door, record:

  • The proposed door width
  • The clear opening
  • Inward or outward swing
  • Left-hand or right-hand operation
  • Available clearance outside and inside the stall

Door swing and hardware placement should be shown clearly on the restroom layout.

Standard commercial bathroom partition doors and panels are commonly between 55 and 58 inches tall. They are typically installed 12 to 14 inches above the finished floor, depending on the material and partition system.

The final height can vary based on:

  • Partition material
  • Mounting style
  • Standard or increased-privacy design
  • Ceiling height
  • Project specifications

Increased-privacy partitions use taller doors and panels with smaller gaps above and below the components. Floor-to-ceiling systems can provide additional stability and privacy in busy commercial restrooms.

Confirm the selected material and mounting style before using standard height measurements for your project.

The mounting style affects the partition’s appearance, support requirements and installation.

Overhead-Braced Partitions

Overhead-braced partitions attach to the floor and use a metal headrail across the top for added support. This is the most common mounting style because it works well in many commercial restroom layouts.

Floor-Mounted Partitions

Floor-mounted partitions anchor to the floor without an overhead rail. They provide a clean appearance but require a strong, level floor for proper support.

Ceiling-Hung Partitions

Ceiling-hung partitions leave the floor clear, which can make cleaning easier. This style requires sufficient structural support above the ceiling.

Floor-to-Ceiling Partitions

Floor-to-ceiling partitions anchor at both the floor and ceiling. They offer additional stability and work well in high-traffic facilities.

Accurate measurements help ensure your bathroom partitions fit correctly and operate as intended. Measure from finished surfaces and record all dimensions in inches.

Record the complete area where the bathroom partitions will be installed, including:

  • Wall-to-wall width
  • Front-to-back depth
  • Ceiling height
  • Floor type
  • Wall construction
  • Location of toilets and fixtures

Measure the room in several places. Walls and floors are not always perfectly straight or level.

Measure the planned width of each stall from finished wall to partition, or from partition to partition.

Record each stall separately instead of assuming all stalls have the same width. Small differences can affect panel, pilaster and door sizes.

Measure from the finished back wall to the proposed front of the stall. The front line is where the doors and pilasters will be installed.

Allow enough room for:

  • Toilet placement
  • Door operation
  • Required clearances
  • User movement
  • Accessible turning and maneuvering space

Measure from the finished side wall to the centerline of each toilet. Also note whether the toilet is wall-hung or floor-mounted.

The toilet type and location are especially important when determining accessible stall depth and clearance.

Clearly mark whether each door will swing inward or outward. Also record whether the door should operate from the left or right.

Make sure the door will not interfere with:

  • The toilet
  • Grab bars
  • Sinks or accessories
  • Other stall doors
  • Required accessible clearances

Include anything that may interfere with the partitions or hardware, such as:

  • Pipes
  • Baseboards
  • Wall tile
  • Floor drains
  • Radiators
  • Vents
  • Windows
  • Electrical outlets
  • Existing bathroom accessories

Provide the size and exact location of each obstruction.

Choose the mounting style before finalizing the measurements. Floor construction, ceiling structure and overall room height can affect which mounting styles will work.

If you are unsure, send your restroom measurements and layout to our team for review.

Request a Free Partition Quote
Fast, accurate, and tailored to your layout.

ven a small measurement mistake can lead to:

  • Incorrect door or panel sizes
  • Hardware alignment problems
  • Doors that do not open properly
  • Installation delays
  • Costly replacement parts
  • Accessibility issues

Measure from finished walls, tile and flooring—not unfinished construction surfaces. Check every measurement at least twice and use the smallest measurement when walls are uneven.

Take every measurement at least twice. Measure in multiple locations when a wall or floor appears uneven.

Tile, drywall and wall panels reduce the available space. Always use finished dimensions when possible.

An inward-swinging door needs enough room to clear the toilet and required floor space. Outward-swinging doors need sufficient clearance outside the stall.

Pipes, vents, baseboards and bathroom accessories can interfere with panels, pilasters and mounting hardware.

Measure each stall individually. Small differences in wall placement or toilet location can change the required partition sizes.

Do not rely on a standard layout without checking the actual space. Accessible stalls must meet requirements for width, depth, door clearance, toilet placement and maneuvering space.

The material does not usually change the required ADA clearances, but it can affect component thickness, available sizes and installation details.

We offer:

Powder-coated steel offers an economical option for many commercial restrooms. Solid plastic provides excellent moisture resistance and works well in high-traffic or humid environments. Stainless steel offers a clean, professional appearance with reliable performance.

A standard commercial bathroom stall is commonly 36 inches wide and 60 inches deep. Actual dimensions can vary based on the restroom layout and local requirements.

A standard commercial stall is commonly 36 inches wide. Confirm the required size with the applicable building code and project specifications.

A wheelchair-accessible stall must generally be at least 60 inches wide. The minimum depth is typically 56 inches with a wall-hung toilet or 59 inches with a floor-mounted toilet.

Yes. Commercial bathroom partitions can be sized for the restroom’s finished dimensions, material, mounting style and layout.

Not sure whether your bathroom stall dimensions are correct? Send us your measurements, sketch or restroom layout. Our experienced team can review the information and help determine the partition sizes needed for your project.

We supply powder-coated steel, solid plastic and stainless steel bathroom partitions for commercial restrooms nationwide.